Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Drug Test Anal ; 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38205661

RESUMO

For antidoping laboratories, the determination of an illicit testosterone (T) administration in urine samples remains a difficult process as it requires the determination of the exogenous origin by carbon isotope ratios (CIRs) of testosterone and its metabolites. As a complement to the urinary analysis, targeting testosterone esters (e.g. testosterone undecanoate [TU]) in serum samples by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) could represent a simpler approach compared with isotope ratio mass spectrometry (IRMS). These two approaches both lead to the direct detection of the administration of exogenous T but with a difference in effort and complexity of the analysis. To compare the detection window obtained with the two strategies, serum and the corresponding urine samples collected from an administration study with oral TU were analysed. Results showed that, at all timepoints where the intact TU was detected in serum, the CIRs of urinary steroids were also not in agreement with an endogenous origin. IRMS analysis required more effort but resulted in slightly longer detection windows than the ester analysis. Finally, this comparison study showed that, in the presence of a suspicious urinary steroid profile, the LC-MS/MS steroid esters analysis in the corresponding serum samples can be very helpful. If steroid esters are not detected, the IRMS analysis can then be conducted on the urine sample afterwards. Overall, the combination of matrices might facilitate the detection of prohibited T administration in sports, especially for athletes with naturally low T/E ratios.

2.
Biomolecules ; 14(1)2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38254680

RESUMO

Sjögren's syndrome dry eye (SSDE) is a subset of Sjögren's syndrome marked by dry eye symptoms that is distinct from non-Sjögren's syndrome dry eye (NSSDE). As SSDE can lead to severe complications, its early detection is imperative. However, the differentiation between SSDE and NSSDE remains challenging due to overlapping clinical manifestations. This review endeavors to give a concise overview of the classification, pathophysiology, clinical features and presentation, ocular and systemic complications, clinical diagnosis, and management of SSDE. Despite advancements, limitations in current diagnostic methods underscore the need for novel diagnostic modalities. Thus, the current review examines various diagnostic biomarkers utilized for SSDE identification, encompassing serum, salivary, and tear analyses. Recent advancements in proteomic research and exosomal biomarkers offer promising diagnostic potential. Through a comprehensive literature review spanning from 2016 to 2023, we highlight molecular insights and advanced diagnostic modalities that have the potential to enhance our understanding and diagnosis of SSDE.


Assuntos
Síndromes do Olho Seco , Síndrome de Sjogren , Humanos , Síndrome de Sjogren/diagnóstico , Proteômica , Síndromes do Olho Seco/diagnóstico , Olho , Biomarcadores
3.
Mikrochim Acta ; 190(11): 447, 2023 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-37864774

RESUMO

Flexible silver substrates were made by in situ reduction of silver nanoparticles in bacterial cellulose membranes using the unique advantage of dopamine. Subsequently, we modified the substrate with 4-mercaptophenol (4-MP), a molecule capable of specifically recognizing ClO-, and its corresponding SERS signal changes with the concentration of hypochlorite, thus allowing the quantitative detection of ClO- content. The method showed a negative linear correlation (R2 = 0.9567) with the SERS intensity at 1077 cm-1 over the concentration range 0.5-100 µM, and the detection limit was 0.15 µM. The RSD of the SERS intensity at 1077 cm-1 under five batches was 4.2%, which proved the good reproducibility of P-BCM-Ag NP-MP. Finally, the P-BCM-Ag NPs were used for the detection of hypochlorite in cell contents, artificial urine, and clinical serum samples, utilizing spike experiments in all three environments. The recoveries were in the range 90-110% indicating the accuracy of the method for the detection of hypochlorite and validating the promising application of this assay for practical detection in intricate biological samples.


Assuntos
Celulose , Nanopartículas Metálicas , Dopamina , Ácido Hipocloroso , Prata/química , Nanopartículas Metálicas/química , Reprodutibilidade dos Testes , Análise Espectral Raman/métodos
4.
Mikrochim Acta ; 190(8): 307, 2023 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-37466749

RESUMO

Porous highly boron-doped BCN (p-BCN) was produced by using a boron cluster salt (closo-[B12H12]2-) as the boron-based precursor and SiO2 as a hard template. The synthesized p-BCN was used in an electrochemical sensor for the ultrasensitive and highly selective detection of morphine (MOP). The optimal conditions for MOP detection were determined by optimizing the experimental conditions. Under these optimal conditions, the p-BCN-based sensor exhibited excellent MOP detection performance (working potential of 0.2 V). Specifically, it showed a detection range of 0.05 to 200 µM and a detection limit of 17.8 nM. Notably, the p-BCN-based electrochemical sensor was successfully applied to the determination of MOP in human blood, and the results showed satisfactory recovery and accuracy. Therefore, this sensor can be used as an effective platform for the detection of MOP in human blood samples.


Assuntos
Boro , Morfina , Humanos , Porosidade , Dióxido de Silício , Eletrodos
6.
Biomed Chromatogr ; 36(4): e5315, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34981553

RESUMO

A novel MS-based analytical method for simultaneous analysis of the antiviral drugs acyclovir, its metabolite 9-carboxymethoxymethylguanine, ganciclovir, and penciclovir in human serum is described. These antiviral drugs are active against herpes virus infections. Acyclovir and penciclovir are regarded as safe and effective medicines with mild side effects such as headache and gastrointestinal discomfort, and ganciclovir is regarded as more toxic and is known to cause, for example, bone marrow suppression. Acyclovir's main metabolite 9-carboxymethoxymethylguanine is a presumptive neurotoxin and should be monitored in patients with impaired renal function or in cases with neurotoxic symptoms. A sample was prepared using protein precipitation with 1% formic acid in methanol containing isotopically labeled internal standard. Chromatographic separation on a biphenyl column and mass spectrometric detection were performed in multiple reaction monitoring (MRM) mode on a Xevo TQ-S micro with ESI in positive ion mode, within 3 min. Inter-day assay accuracies for the quality controls varied between 95 and 104% and intra-day assay between 93 and 105%. Inter-day and intra-day assay imprecision for the quality controls ranged between 1.4 and 4.2% and 1.7 and 6.5% respectively. The lower limit of quantification for all four substances was 0.156 µmol/L. It is an accurate and reproducible method for therapeutic drug monitoring.


Assuntos
Aciclovir , Ganciclovir , Cromatografia Líquida/métodos , Guanina/análogos & derivados , Humanos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
7.
Mikrochim Acta ; 188(11): 371, 2021 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-34625854

RESUMO

A one-pot hydrothermal synthesis of three-dimensional (3D), large-area, bimetallic oxide NiCo2O4 (NCO) microflowers has been developed as a novel substrate for surface-enhanced Raman scattering (SERS) detection of flutamide in biological fluids. The 3D flower-like morphology of the NCO is observed via FESEM micrographs, while the orthorhombic phase formation is confirmed through XRD spectra. Due to the presence of multiple coordination cations of the 3D NCO microflowers (such as Ni2+ and Co2+), the high surface area and surface roughness, the NCO-modified indium tin oxide (NCO/ITO) SERS substrate exhibits a linear detection range from 0.5-500 nM with a low limit of detection (LOD) of 0.1 nM. The SERS substrate provides a high enhancement factor of 1.864 × 106 with an accumulation time of 30 s using a laser source of λ = 532 nm, which can be ascribed to the excellent and rapid interaction between the flutamide molecule and the NCO microflower substrate that leads to photoinduced charge transfer (PICT) resonance. The NCO/ITO substrate exhibits excellent homogeneity and high chemical stability. Besides, the substrate displays an excellent selectivity to flutamide molecules in the existence of other metabolites such as urea, ascorbic acid (AA), glucose, NaCl, KCl, CaCl2, and hydroxyflutamide. The NCO/ITO substrate is successful in the trace-level detection of flutamide in simulated blood serum samples. The strategy outlined here presents a novel strategy for the efficacy of transition metal oxides (TMOs) based electrodes useful for a wide variety of bioanalytical applications.


Assuntos
Análise Espectral Raman
8.
Mikrochim Acta ; 188(11): 386, 2021 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-34664145

RESUMO

A fluorescent paper strip immunoassay in conjunction with carbon nanodots@silica (CND@SiO2) as a label was developed for the quantitative measurements of human serum amyloid A1 (hSAA1) in serum at clinically significant concentrations for lung cancer diagnosis. Monodispersed CND@SiO2 was prepared by cohydrolysis between silane-crosslinked carbon nanodots and silica precursors via the Ströber method and further attached covalently to anti-hSAA1 (14F8) monoclonal antibody [anti-hSAA1(14F8)] specific to the hSAA1 target. The hSAA1 concentrations were then determined by quantifying the blue fluorescence intensity upon 365 nm excitation of the captured hSAA1 with anti-hSAA1(14F8)-CND@SiO2 conjugates in the test line on a paper strip where anti-hSAA1 (10G1) monoclonal antibody was physisorbed. The developed fluorescent paper strip with CND@SiO2 can detect hSAA1 at concentrations ranging from 0.1 to 5 nM (R2 = 0.995), with a limit of detection of  0.258 nM in 10 mM phosphate buffer pH 7.4 containing human serum albumin. The performance of  recovery (90.98-109.17%) and repeatability (coefficients of variation < 8.46%) obtained was also acceptable for quantitative determinations. The platform was employed for direct determination of hSAA1 concentrations in undiluted serum samples from lung cancer patients (relative standard deviation (RSD) < 7.46%) and healthy humans (RSD < 3.96%). The results were compared with those obtained using a commercially available enzyme-linked immunosorbent assay alongside liquid chromatography with tandem mass spectrometry measurements.


Assuntos
Carbono/química , Imunoensaio/métodos , Proteína Amiloide A Sérica/metabolismo , Dióxido de Silício/química , Fluorescência , Humanos
9.
Int J Mol Sci ; 22(13)2021 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-34203517

RESUMO

Metabolites and enzymes involved in the kynurenine pathway (KP) are highly promising targets for cancer treatment, including gastrointestinal tract diseases. Thus, accurate quantification of these compounds in body fluids becomes increasingly important. The aim of this study was the development and validation of the UHPLC-ESI-MS/MS methods for targeted quantification of biologically important KP substrates (tryptophan and nicotinamide) and metabolites(kynurenines) in samples of serum and peritoneal fluid from gastric cancer patients. The serum samples were simply pretreated with trichloroacetic acid to precipitate proteins. The peritoneal fluid was purified by solid-phase extraction before analysis. Validation was carried out for both matrices independently. Analysis of the samples from gastric cancer patients showed different accumulations of tryptophan and its metabolites in different biofluids of the same patient. The protocols will be used for the evaluation of tryptophan and kynurenines in blood and peritoneal fluid to determine correlation with the clinicopathological status of gastric cancer or the disease's prognosis.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cinurenina/metabolismo , Neoplasias Gástricas/metabolismo , Espectrometria de Massas em Tandem/métodos , Líquido Ascítico/metabolismo , Humanos , Ácido Tricloroacético/metabolismo , Triptofano/metabolismo
10.
J Equine Vet Sci ; 99: 103401, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33781411

RESUMO

The purpose of this study was to investigate the profile change of serum trace and major elements, and biochemical and hematological parameters in jennies during late pregnancy and early lactation. Twenty-five healthy Chinese Liaoxi jennies were used in late pregnancy and early lactation. Results showed that the levels of Fe, total protein (TP), and aspartate aminotransferase (AST) were highly variable interindividual among the jennies. Early lactating jennies showed significantly lower serum levels of K, Se, AST, total cholesterol (TC), and triglyceride than late pregnant jennies (P < .05). Principal component analysis identified six and five principal components of serum mineral and biochemical parameters for late pregnant and early lactating jennies, respectively, which was supported by the cluster analysis findings. Strong clustering of serum Cu-Mn, iPhos-Se-TP, and Ca-Zn-alanine aminotransferase-TC was found in the late pregnant jennies, and strong clustering of serum Ca-Zn-Se-Mn-albumin, Na-Fe-AST-triglyceride, and K-Mg-Cu-TP was observed in the early lactating jennies. The study suggests a significant variation in the serum levels of mineral and biochemical parameters in late pregnant and early lactating jennies, which is valuable in estimating their physiological status and providing proper health care.


Assuntos
Equidae , Lactação , Animais , Feminino , Minerais , Gravidez
11.
Mikrochim Acta ; 188(2): 34, 2021 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-33417060

RESUMO

Nickel sulfide nanoworm (Ni3S2 NW) network architecture was directly grown on the poly (3,4-ethylenedioxythiophene)-reduced graphene oxide hybrid films (PEDOT-rGO HFs) modified on glassy carbon electrode (GCE), acting as a binder-free sensor for high-performance non-enzymatic glucose monitoring. The sensor exhibited the satisfactory sensitivity (2123 µA mM-1 cm-2), wide linear range (15~9105 µM), low detection limit (0.48 µM), and rapid response time (< 1.5 s) at a potential of 0.5 V (vs. SCE) in 0.1 M NaOH and possessed good selectivity, reproducibility, and stability. The enhanced electrocatalytic activity of the sensor towards glucose oxidation was attributed to the particular morphology, satisfying hydrophilic nature, strong combination between Ni3S2 NWs, PEDOT-rGO, and bare GCE. Moreover, it can be used for assaying glucose in human serum samples without dilution, indicating potential for clinical diagnostic applications. Graphical abstract Nickel sulfide nanoworms (Ni3S2 NWs)/poly (3,4-ethylenedioxythiophene)-reduced graphene oxide hybrid films (PEDOT-rGO HFs) were used to construct a binder-free high-performance non-enzymatic glucose sensor with satisfactory sensitivity, wide linear range, low detection limit, good selectivity, amazing reproducibility, and stability.


Assuntos
Glicemia/análise , Técnicas Eletroquímicas/métodos , Nanopartículas Metálicas/química , Níquel/química , Glicemia/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Técnicas Eletroquímicas/instrumentação , Eletrodos , Grafite/química , Humanos , Limite de Detecção , Oxirredução , Polímeros/química , Reprodutibilidade dos Testes
12.
ACS Appl Mater Interfaces ; 13(1): 1914-1920, 2021 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-33378159

RESUMO

Graphdiyne (GD) is a new kind of carbon nanomaterial which has carbon-carbon triple bonds to form a layered structure. Here, we report the application of GD as the matrix for small molecule analysis in laser desorption ionization mass spectrometry (LDI MS). The GD matrix displayed two advantages: little background in the low mass range and good molecular ion signal in negative ion mode for many small molecules, e.g., fatty acids, amino acids, peptides, and drugs can be obtained in negative ion mode. By comparing the signal intensity of tetraphenylborate and juglone with and without GD existing, it was found that GD can enhance both of the desorption efficiency and ionization efficiency in LDI. Through analysis of the serum samples from liver cancer patients and healthy people, the GD-assisted LDI MS results showed that fatty acids could be used as potential biomarkers for the early diagnosis of liver cancer.


Assuntos
Aminoácidos/análise , Ácidos Graxos/sangue , Grafite/química , Compostos Orgânicos/análise , Preparações Farmacêuticas/análise , Biomarcadores Tumorais/sangue , Humanos , Limite de Detecção , Neoplasias Hepáticas/sangue , Neoplasias Hepáticas/diagnóstico , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
13.
Mikrochim Acta ; 187(11): 629, 2020 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-33123813

RESUMO

A base amount-dependent fluorescence enhancement-based strategy is put forward to determine vascular endothelial growth factor 165 (VEGF165) in human serum by the use of hairpin DNA-silver nanoclusters (hDNA-AgNCs) and oxidized carbon nanoparticles (CNPs). The hDNA-AgNCs aptasensing probe consists of AgNCs-contained hairpin loop (that generates a fluorescence signal), hairpin stem (that makes the structure stable), and the terminal aptamer 1 (that recognizes the target together with aptamer 2). It has been demonstrated that the fluorescence intensity of hDNA-AgNCs is ~ 3-fold stronger than that of single-stranded DNA-AgNCs (ssDNA-AgNCs), and hDNA-AgNCs have a strong dependence of fluorescence enhancement on the base amount in hairpin stem and loop. Upon the addition of oxidized CNPs, the terminal aptamer 1 of hDNA-AgNCs can adsorb onto the surface of oxidized CNPs via π-π stacking, and the fluorescence of hDNA-AgNCs (with excitation/emission maxima at 490/567 nm) is quenched via fluorescence resonance energy transfer (FRET). When aptamer 2 and VEGF165 are subsequently added, aptamer 1, VEGF165, and aptamer 2 reassemble into an intact tertiary structure, and the fluorescence is recovered because hDNA-AgNCs are far away from the surface of oxidized CNPs and the FRET efficiency decreases. Under the optimized conditions, the aptasensing probe can selectively assay VEGF165 with a detection limit of 14 pM. The results provide a label-free and sensitive method to monitor VEGF165 in human serum. Schematic representation of the strong dependence of fluorescence enhancement on base amount in stem and loop of hairpin DNA-silver nanoclusters. The probe can be used to assay vascular endothelial growth factor 165 (VEGF165) and give a judgment whether human serum VEGF165 is at a normal or abnormal level for clinical diagnosis.


Assuntos
Nanopartículas Metálicas/química , Soro/química , Prata/química , Fator A de Crescimento do Endotélio Vascular/química , Feminino , Humanos , Neoplasias Ovarianas/sangue , Neoplasias Ovarianas/metabolismo , Isoformas de Proteínas , Sensibilidade e Especificidade , Espectrometria de Fluorescência/métodos
14.
Int J Mol Sci ; 21(18)2020 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-32961980

RESUMO

Several research disciplines require fast, reliable and highly automated determination of pharmaceutically active compounds and their enantiomers in complex biological matrices. To address some of the challenges of Capillary Electrophoresis (CE), such as low concentration sensitivity and performance degradation linked to the adsorption and interference of matrix components, CE in a hydrodynamically closed system was evaluated using the model compounds Pindolol and Propranolol. Some established validation parameters such as repeatability of injection efficiency, resolution and sensitivity were used to assess its performance, and it was found to be broadly identical to that of hydrodynamically opened systems. While some reduction in separation efficiency was observed, this was mainly due to dispersion caused by injection and it had no impact on the ability to resolve enantiomers of model compounds even when spiked into complex biological matrix such as blood serum. An approximately 18- to 23-fold increase in concentration sensitivity due to the employment of wide bore capillaries was observed. This brings the sensitivity of CE to a level similar to that of liquid chromatography techniques. In addition to this benefit and unlike in hydrodynamically opened systems, suppression of electroosmotic flow, which is essential for hydrodynamically closed systems practically eliminates the matrix effects that are linked to protein adsorption.


Assuntos
Eletroforese Capilar/métodos , Soro/química , Eletroforese Capilar/instrumentação , Hidrodinâmica , Preparações Farmacêuticas , Pindolol/análise , Propranolol/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software , Estereoisomerismo
15.
Mikrochim Acta ; 187(8): 482, 2020 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-32749541

RESUMO

A composite, reduced graphene oxide (rGO) doped with silver nanoparticles (Ag NPs), was prepared by using binary reductants of sodium citrate and hydrazine hydrate. Carbon quantum dots (CQDs) synthesized by papaya peel combined with silver ions to form a CQDs-loaded silver nanoparticle (AgCQDs) nanocomposite. Polymer nanospheres (PNS) were generated via the infinite coordination polymer of ferrocene dicarboxylic acid and employed as carriers to load AgCQDs. The prepared AgCQDs@PNS-PEI has good biocompatibility and electrical conductivity and can be used as a matrix for the immobilization of a secondary antibody (Ab2). A sandwich-type electrochemiluminescence (ECL) immunosensor using AgCQDs@PNS-PEI nanocomposite as probe has been developed for the detection of human chorionic gonadotropin (HCG). The proposed immunosensor exhibits a linear range from 0.00100 to 500 mIU mL-1 and the detection limit is 0.33 µIU mL-1 (S/N = 3) under optimal conditions. The sensor exhibits excellent selectivity, good reproducibility, and high stability. These features demonstrate that the proposed method has promising potential for clinical protein detection and displays a new strategy to fabricate an immunosensor. Graphical abstract.


Assuntos
Gonadotropina Coriônica/sangue , Técnicas Eletroquímicas/métodos , Imunoensaio/métodos , Medições Luminescentes/métodos , Nanosferas/química , Pontos Quânticos/química , Adulto , Anticorpos Imobilizados/imunologia , Carbono/química , Carica/química , Gonadotropina Coriônica/imunologia , Feminino , Frutas/química , Humanos , Limite de Detecção , Nanopartículas Metálicas/química , Nanocompostos/química , Polietilenoimina/química , Reprodutibilidade dos Testes , Prata/química
17.
Naunyn Schmiedebergs Arch Pharmacol ; 393(12): 2453-2461, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32725284

RESUMO

This study reports an effort to synthesize biocompatible zinc oxide nanoparticles using sol-gel method and its influence on hematological and serological profile of Catla catla fish. Hexagonal wurtzite structure and crystallite size of ZnO-NPs was identified by using XRD in the range of 19 to 20 nm. Moreover, the irregular and non-uniform surface of these NPs was found using SEM. The different stretched and vibrational mode (ZnO, OH, CO, and H-O-H) was identified by using FTIR analysis. UV-visible spectroscopy confirmed absorbance of the blue shift in the range 340 nm. Bioassay of ZnO-NPs on Catla catla was performed and nano ZnO was given through intraperitoneal injections at 0, 25, 50, 75, and 100 µg/g body weight doses. Analysis of fish blood samples indicated an increase in WBCs and leukocytes while the differential effect on monocytes. On the other hand in response to varying ZnO concentrations, an increase in RBCs, hemoglobin, and HCT was evident. Serum analysis revealed an increase in urea concentration while a reduction in creatinine, ALT, and AST. In an overall assessment, nano-ZnO supplementation at 25 to 100 µg/g body weight differentially affected hematological and serum biochemical profile of thaila fish. Graphical abstract.


Assuntos
Nanopartículas Metálicas/administração & dosagem , Óxido de Zinco/administração & dosagem , Óxido de Zinco/sangue , Animais , Contagem de Células Sanguíneas/métodos , Relação Dose-Resposta a Droga , Peixes , Injeções Intraperitoneais , Nanopartículas Metálicas/química , Óxido de Zinco/síntese química
18.
Biosens Bioelectron ; 164: 112329, 2020 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-32553354

RESUMO

Herein, a novel turn-off fluorescent aptasensor was developed for selective detection of ampicillin (AMP) at picomolar level based on 3,4,9,10-perylenetetracarboxylic acid diimide (PTCDI) as an affordable and low-cost fluorophore. This aptasensor was designed using aptamer, its complementary strand (CS) and gold nanoparticles (AuNPs). The principle of the sensing method is a decrease in the fluorescence intensity of PTCDI in the presence of free CS. Following the addition of AMP, Aptamer/CS-modified AuNPs releases CS and so, the fluorescence intensity of PTCDI is reduced. The designed analytical method indicated a good linear range from 100 pM to 1000 pM and a limit of detection (LOD) of 29.2 pM was obtained. Furthermore, the sensing strategy indicated satisfactory results for the detection of AMP in the spiked human serum samples. By changing the sequences of aptamer and its CS, the presented analytical approach can be easily applied for detection of other antibiotics.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Nanopartículas Metálicas , Ampicilina , Ouro , Humanos , Limite de Detecção
19.
Int J Gen Med ; 13: 243-247, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32547166

RESUMO

OBJECTIVE: The aim of this study is to determine the distribution of the results of routine laboratory tests for the diagnosis of pneumonia in children in Khorramabad. METHODS: This is a cross-sectional study and was performed on 650 children with pneumonia who were referred to Shahid Madani Hospital. From patients' test results, the following data were recorded: whether the results were normal or not, age, sex, serotype, history of diabetes mellitus, and the presence of urinary and digestive tract symptoms. RESULTS: There was no difference in the prevalence of pneumonia, gender-wise, whereas 40% of the patients were under 2 years. In addition, 53.7% of the patients were presented with leukocytosis. From the blood test, blood urea nitrogen, creatinine, sodium, and potassium were normal in most of the patients. Stool examination, urine analysis, urine culture, erythrocyte sedimentation rate, C-reactive protein, and blood sugar were also normal in these patients. CONCLUSION: Children under the age of 2 years are more susceptible to lung infections. Findings from blood tests such as leukocytosis are useful for making initial diagnosis other than computed tomography scan. Other lab tests might not give any useful results. In addition, a closer examination of the urinary system and digestive tract involvement is recommended, prior to urine or stool analysis.

20.
Toxics ; 8(2)2020 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-32414073

RESUMO

Bisphenol A (BPA) is leached out from plastic infant feeding bottles that are filled with warm milk/water due to high temperatures, exposing the infants to BPA. The present study aims to understand the effects of ingestion of BPA leached from plastic infant feeding bottle and delineate the underlying mechanisms in rats. In this study, adult rats of Wistar strain were divided into 3 groups. In the first group, the rats consumed normal food and tap water ad libitum. In the second group, the rats ingested BPA (20 µg/kg bodyweight/day, orally). In the third group, the rats drank water leached from plastic infant feeding bottles. After 30days, tests involving biochemical parameters, histopathological examination, and oxidative stress enzyme markers were performed, and the levels of BPA in plastic-leached water were estimated by HPLC analysis. There were significant biochemical changes in the form of increased alkaline phosphatase (ALP), creatine kinase-muscle/brain (CK-MB), and lactate dehydrogenase (LDH) levels in both treated groups as compared to control group, accompanied by structural damage to the vital organs, and lipid peroxidation, glutathione reductase, and catalase activity were also high in the treated groups. Further, the BPA concentration in plastic leached water was estimated to be 0.1 ± 0.02 µg/mL.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...